Solution of Dupont ReliatraN® dry type transformer

 

1.Reliablility

1.1Better tolerance in temperature rise - longer life cycle of the product
The main insulation material is the patent-Nomex that produced by Du Pont Company. It is Class C insulation material (220¡æ), meaning the transformer can operate normally where the ambient temperature is 40¡æ, average temperature rise is 150K and the highest temperature tolerance is 30¡æ.

Our excitation transformer is the Class H (maximum running temperature is 180¡æ), the design average temperature rise is lower than 100K, but the average temperature rise of general Class H product is 125K. Therefore, it has better tolerance in temperature rise so that it will guarantee the service life of product.

1.2  Over-excitation ,anti-high frequency radiation
   When the excitation transformer is in use, the system will tent to overexcite. Large-scale excitation transformer requires to assuring two times of excitation voltage when the generator's end voltage drops to 0.8 times of rated voltage. To maximize the safety and the reliability, we can calculate the excitation transformer secondary rated voltage according to strong excitation condition, the valid value of the excitation transformer secondary rated current can be worked out by the maximum continuous excitation system output, and then we can determine the maximum continuous excitation power.

1)   Because the excitation transformer winding current is not sinusoidal waveform (contains high-order harmonics pulses waveform), it will cause the imbalance between rectifier transformer capacity and the DC transmission power. The copper loss and iron loss produced by the harmonics current are greater than those produced by winding rated current, and secondary winding capacity is greater than primary's during poly-phase rectification. Therefore, compare with ordinary distribution transformers, excitation transformers must meet the higher requirements in terms of electric density, magnetic field density, temperature rise, capacity and overload ability.

In our design, not only we installed the static electric isolation shield between primary and secondary windings, also adopted higher winding insulation level than ordinary distribution transformer.

2) Our excitation transformer adopts Nomex?insulation material. In that Nomex?have the remarked anti-high frequency radiation ability, it will intact by 800Mgy plasma radiation, and its electric and mechanical ability will never be changed even after 8 times radiated. Such as the high frequency transformer insulation material of microwave oven is Nomex?so high frequency radiation will hardly shorten the service life of product.

3) When loaded with high-order harmonics, transformer will produce high heat point temperature. Usually we will adopt the solution of temperature drop to compensate and thus, increase the sizes of the equipments and waste resources. The dry type transformer, which uses Nomex?insulation system has better heat tolerance, can endure high heat and therefore prolong the life of the transformer.

1.3 High anti-short circuit and thunder impulse

   The low voltage winding is foil type and the high voltage winding is multi-layer cylinder type. Just consider from the structure, the anti-sudden short circuit ability is so far stronger than the spiral pancake winding together rolled by several flat wires or cylinder winding. Furthermore, our products also have been processed by VPI (Vacuum Pressure Varnishing Technology), so that guarantee the mechanical characteristics.

1.4 Low partial discharge
    Partial discharge means that there is just discharge partly in the effect of electric field, but not be struck, and this phenomenon is partial discharge.

    Normally partial discharge is caused by compact electric field in the inner or on the surface of the insulator. Generally, this discharge phenomenon is constant impulse less than 1s. However, it also possibly appears as a continual phenomenon, for instance the non-impulse discharge in the gas medium. Normally, this type of discharge cannot be tested.   

    During 2001-2003, in Thailand, there were so many epoxy resin dry type transformers crazing, partial discharge higher suddenly, which disturbed the daily life seriously. Therefore, Thailand government revised the dry transformer standard. The new standard definitely prescribes that dry transformer must pass the partial discharge test before selling. Meanwhile the same problems also emerged in Europe. However, the most dry type transformers were insulated by Nomex?material, which could solve such problems because of the perfect electrical and mechanical characteristics itself. Therefore, American never made any regulations about the partial discharge on dry type transformer.  

The different insulation materials tend to the different attitudes for the same problem.

Compared with other insulation materials, the inductivity of Nomex?is very low.

 

Material

Inductivity

Material

Inductivity

Nomex?/P>

1.5-2.5

Air

1.0

Epoxy Resin

4.6

Polyester Resin

3.1-3.2

Inorganic Material

3.0-5.0

Transformer Oil

2.2

Glass Fiber

5.0-6.0

Silicon Oil

2.7

Fiber Paper

4.5

Polyester Film

3.1


The relationship between the electrical field strength and the insulation inductivity is as follows:

Epoxy resin  ¦Å=4.5      Nomex? ¦Å=1.5        Air  ¦Å=1


U=10000V;  :B 0=B1

Voltage U=10000V; Distance:B 0(Air)=B1(Solid)

(1)  In the system of Epoxy resin and air
1818.18V; Epoxy resin load: 1818.18V
8181.82V;  Air load: 8181.82V
As the place where there has air can become the part where lead the whole insulation system to be broken because of the huge voltage.


(2) In the system of Nomex@ and air

Nomex@ load: 400V;
Air load: 600V

If there is air in system, the voltage of Nomex?and air system will reduce 26.7% rather than epoxy resin and air system's. Because of the inductivity of Nomex?is close to the air's, so the distribution of the electric field is evenly, thus it cannot produce the partial discharge even when there are air bubbles in the insulation system.

The air bubbles in the insulator interior or on its surface are the most possible things to result in partial discharge. For the inductivity of air is always lower than solid and liquid's. Under electrical field, distribution of electric field strength is in reverse proportion to inductivity.

That means if there are air bubbles exist in liquid or solid medium, the electric strength in air bubble will higher than the electric strength in surrounding medium. The strike electric strength of air bubbles is always lower so much than liquid and solid's under the atmospheric pressure, so air bubble discharge firstly, while other medium still keep insulation. Then the partial discharge will happen.

The dry type transformer insulated by Nomex?can avoid the partial discharge happen because the inductivity of Nomex?is so close to air inductivity that improves the electric field distribution

2. High adaptability
    Because the installation place where the excitation transformer employed have the high humidity (hydroelectric station) and the serious defilement (power plant), the humidity-proof and defilement-proof measures should be given appropriate consideration in the process of transformers' manufacture so as to keep it running normally.

2.1  Anti-sudden cold and anti-sudden heat ability
    Du PonTTM ReliatraN?dry type excitation transformer passed C2 "Climatic Class" in European independent laboratory (CECI) in Milan, Italy. The procedures of test is that putting the transformer into a laboratory (690m3), dropping the temperature of laboratory from + 25¡æ to - 25 ¡æ within 8 hours, and keeping - 25 ¡æ for 12 hours; at that time, the surface of iron has frozen by frost about 2 mm. Then, putting into the 2 times rated current from LV side, and raising temperature from  - 25 ¡æ to 165 ~ 170 ¡æ quickly. Then all the frost turns to water pearl and steam completely. Afterwards, drop the temperature to 25?/FONT>C, start the insulation test with 75% rating voltage and partial discharge test.

 If meet the requirements of test standard, it means that the transformer passed C2 test.


2.2 High humidity-proof and defilement-proof ability, no performance decline in complicated condition, no crack and no damage in insulation system

The main insulation material of Du PontTM ReliatraNv dry type transformer is Nomex? and it can keep 90% electrical strength under 95% RH. . Meanwhile, a lot mechanical performances of transformer have been improved by this material and it never be influenced by the humidity. In the process of manufacture, Du PontTM ReliatraN?dry type transformer use the  Dow Corning¡¡À silicon resin import from American after the final assembly to keep full winding-sealing.

Silicon resin has more humidity-proof ability thereby guaranteeing the safety and reliability of transformer. The dry type excitation transformer of Du PontTM ReliatraN?passed the E2 "Environmental Class" in European independent laboratory (CESI) in Milan, Italy.

E1:Condensation experiment
   Put the transformer into a airtight room with 150m3, the conductive rate through spray nozzle is the brine atomization gas of 0.1~0.3s/m, and maintain the humidity in lab is more than 93%, preserving time if longer than 6 hours, namely condensation. Afterwards, exert 1.1 times of the rated voltage to transformer for three times within 5 minutes. Keep that every 5 minutes and 5 minutes each time.

No electric arc will be produced in the process of exerting voltage and any serious damage mark will not be allowed. There has not unusual phenomenon in the test, and partial discharge is 10pc, so the transformer passed the E1 class.

E2 Infiltration experiment
   

After 6 hours E1 class condensation test, the second stage test is following:

Keep the indoor temperature is 50?FONT face=Arial> ( +/- 3¡æ ) , relative humidity is 90%( +/-5 % ) , the conductive rate of the brine atomization gas is 0.5 -1.5 S/m. The second stage last 144 hours, and 150 hours in both stages.

In this week, the water fog with high conductivity has permeated all parts of transformer, so it also called moisture infiltration experiment. Deposit it in this condition or abnormal environment for 3 hours, and exert 75% rated work frequency and induction test voltage, and then the partial discharge is measured. Any electric arc or will not be allowed in the course of exerting. Test result meets the requirement, so the product passed the E2 test and reached E2 class.

preserve indoor temperature is 50 ¡æ ( +/- 3¡æ ) , relative humidity is 90% ( +/- 5% ) , the conductive rate of the atomization gas of salt solution is 0.5 -1.5 S/m, in continued 144 hours two stages share 150 hours,

in the time of this near one week lead with electric conduction very high water fog every position that has permeated transformer , so, this stage is again called as moisture infiltration experiment. Under this condition or innormal environment, keep 3 hours , exert the measure level of partial discharge, induction test voltage and the specified work frequency of 75% for transformer. Exert voltage course in should not have electric arc or breakdown phenomenon occur. Satisfy requirement , get E2 level through E2 level experiment.

3.  Safety
    One of the characteristics ReliatraN?technology winding-sealed dry type transformer owned only is that when outside has caught fire, the transformer can extinguish by itself and will not combustion-supporting. Moreover, the fog transparency is high and there is not toxic gas would be released, so it is convenient to put out the fire.

Dupont TM ReliatraN dry type excitation transformer passed the F1 ¡¡ãfire behavior test¡¡À in European independent laboratory " ( CESI )-----put high and low voltage winding into the test box, and place a electrothermal board with 24kw/750¡æ which the distance from the winding is about 175mm.

Meanwhile, placed a semicircle cylindrical metal shield and put an alcohol plate where can fill sufficient alcohol which can burn 20 minutes. In addition, the distance of the alcohol plate from bottom winding is 40mm. Then, light alcohol, electrize the electric board, make them work together, and extinguish the alcohol flame in 20 minutes, and then cut off the electricity of electric board in 40 minutes so as to flame extinguish itself. The whole test time is 60 minutes. During the test, give a record every 2 minutes, including temperature, fog transparency, and the gas flow of air entrance. Moreover, test if there are some corrosive or toxic gas, such as HCL, H2Br, HF, SO2, formaldehyde and so on. Furthermore, give the description of combustion.

Dupont TMTM ( ReliatraN ) Do type excitation transformer to mind sharp metre orchid " European independent laboratory " ( CESI ) F1 that passes " acclimatization ability experiment ", ( the high coil of low voltage ) place in chamber in, is away from coil the place of 175 mm to place a 24 KW and temperature is 750 ¡æ electric board, at the same time behind online circle, place a semicircle column shape metal screen , is away from coil bottom the place of 40 mm to place a alcohol plate , put greatly can burn 20 minutes of alcohol.

Light alcohol, electric board starts electricity , it is gone out that two at the same time take affect in coil and 20 minutes after alcohol flame, give out heat board start electricity continuously, after 40 minutes, electric board broken electricity and flame go out voluntarily. Entire test course is 60 minutes. In this course, it is each to separate the gas rate of flow of 2 minutes of record one temperature, smoke transparency and air import, and detection whether chlorinating hydrogen and cyanogen melt hydrogen , Xiu melt hydrogen and fluorine melt hydrogen, 2 oxidize sulphurs and shell Quan etc. corrosive and poisonous gas as well as describe combustion condition.


4. Friendly to environmental
4.1 No toxic or harmful substance produced in the course of manufacturing and using
    The technology of Class H winding-sealed (SCR series) dry type transformer need not mineral oil, vacuum cast epoxy resin, non-saturated polyester varnishing. In the whole process of manufacturing and using, there are no such pollution problems as dripping, volatilizing and flyblowing, as well as such discharge problems as organic steam or exhaust gas. Therefore, this kind of product is environmental friendly during the process of manufacturing and using.

4.2 Low loss and noise
    The product performance of no load loss and load loss are both better than the National Standard GB/T10228 ¡¡ãDry Type Transformer Technical Parameter and Requirement¡¡À. Low loss product reduce the 10 years operation cost and play a significant role in saving the energy.

1000kVA

National Standard

Products of Yunnan

Reducing Proportion

W No load lossp>

1990

1700

14.6%

Load loss W(145¡æ)

9270

8755

6%

Total loss W

11260

10455

7.1%

Noise(dB)

64

45

30%


   Noise value is low to about 45dB which reduces 30% comparing with the National Standard (GB/T10228) and as well as up to the National First Class Noise Requirement.

4.3  Recycle

Because of the special structure of product, SCR series dry type transformers are easy to be disassembled and recycled and need not the professional recycle organization or large machines. It only need part from the transformer by workers, selecting metals such as copper and iron, then incinerate or bury the Nomex.